Study of Boston Scientific's Carotid WALLSTENT(TM) Monorail(TM) Design Shows Superior Safety Results in Stroke Prevention

Press Releases »

PARIS--21 Jun--PRNewswire - AsiaNet/InfoQuest


Boston Scientific Corporation (NYSE: BSX) today welcomed the results of a new study, led by Dr. Marc Bosiers of Belgium, demonstrating that the closed cell design of Boston Scientific's Carotid WALLSTENT(TM) Monorail(TM) provides superior clinical outcomes compared to open cell carotid stents.(1) Closed cell stents provide greater plaque coverage of the carotid artery, thereby

potentially reducing the risk of a delayed embolism relative to open cell stents. The study was presented at the 60th Annual Meeting of the Society for Vascular Surgery on June 1st by Dr. Joseph Hart, University of Rochester School of Medicine and Dentistry, Rochester, New York, who helped collect the data during his Marco Polo fellowship in Dendermonde, Belgium.

The study compares the clinical results of open versus closed cell carotid stents in 709 patients. At 30-days post procedure, symptomatic patients that received the closed cell stent showed a 4.1 times reduction of stroke, transient ischemic attacks (TIA, a major predictor of stroke) or death -- compared to the open cell stent group. The Carotid WALLSTENT(TM) Monorail(TM)

represented more than 70 percent of the closed cell stents used in this study. Closed cell stents, such as Boston Scientific's Carotid WALLSTENT(TM) Monorail(TM), have overlapping or fully connecting struts and cover 5 to 10 times more of the vascular wall as compared to open cell stents that have both connecting and non-connecting struts.(2)

Dr. Marc Bosiers, AZ Sint Blasius in Dendermonde, Belgium, Principle Investigator of the study, commented to the Society for Vascular Surgery, "There were less adverse events within 30 days with the closed cell stent. The closed cell stent design offers a greater potential to scaffold and support fractured plaque and keep material that could embolize to the brain, or cause small clots, from traveling through the vasculature. Closed cell stents cover a greater percent of the vascular wall in the stented region and have less uncovered cell area. Therefore we would recommend them for symptomatic patients."

Dr. Bosiers also commented that, "Patients are most at risk for stroke during the 30 days after a carotid stenting procedure. The Carotid WALLSTENT(TM) Monorail(TM) demonstrated fewer complications at 30-days compared to open cell stents, likely due to its closed cell design, which offers greater scaffolding and assists in preventing plaque dislodgement."

The study also reported lower rates of major adverse events within 30 days post-procedure in the patient population treated with eccentric filters (non-central axis design), such as Boston Scientific's FilterWire EZ(TM) Embolic Protection System, compared to the population treated with concentric (center axis design) embolic protection devices. Filters are used during the carotid artery stenting procedure to protect the patient's brain from damage caused by plaque debris or small blood clots.

In the study, the overall combined 30-day rate of stroke, TIA, or death for open and closed cell design stents was 3.7 percent. The overall rates of stroke or death at 30-days, one year and three years were 1.4 percent, 6.0 percent and 15.1 percent, and restenosis rates were 0.2 percent, 0.9 percent and 5.6 percent, respectively. There was no difference in rates of restenosis

(re-narrowing of a previously opened vessel) between symptomatic and asymptomatic patients.

"These results should give physicians great confidence when treating their patients with the Carotid WALLSTENT(TM) Monorail(TM) and FilterWire EZ(TM) Embolic Protection System," said Jeff Goodman, President Boston Scientific International. "The excellent results from this trial build on the existing clinical evidence for using these devices to treat patients with carotid

artery disease and explain why the Carotid WALLSTENT(TM) Monorail(TM) and FilterWire EZ(TM) maintain the number one market share position outside the United States."

Carotid arteries, located on either side of the neck, are the main conduit for blood flow to the brain. When narrowing occurs, patients are at risk for stroke -- the third leading cause of death, and the leading cause of disability worldwide.(3) Carotid artery stenting is a minimally-invasive procedure in which a stent is delivered to the site of the blockage and expanded to open the carotid artery and restore blood flow.

Boston Scientific is a worldwide developer, manufacturer and marketer of medical devices whose products are used in a broad range of interventional medical specialties. For more information, please visit: http://www.bostonscientific.com .

REFERENCES:

1) Bosiers, Peeters, Hart et al. Do Device Characteristics Impact Outcome In Carotid Artery Stenting? Presented at the 2006

Vascular Annual Meeting, Philadelphia.

2) Boston Scientific bench tests.

3) http://www.who.int/cardiovascular_diseases/en/

cvd_atlas_16_death_from_stroke.pdf

SOURCE Boston Scientific International

/CONTACT: Geraldine Varoqui, Boston Scientific PR Manager International,

Tel +49-2102-489-461, Mobile +49-170-782-85-58, [email protected] ; OR Maren

Koban, BSC press office, Tel +44-(0)-20-7973-4497,

Mobile +44-(0)-771-3631-514, [email protected] /

/Website: http://www.bostonscientific.com /

--Distributed by AsiaNet ( www.asianetnews.net )--


ข่าวBoston Scientific+o:asnวันนี้

เมดพาร์ค จัดสัมมนาวิชาการ Cardiac Arrhythmia Conference : Advances in Diagnosis and Management of Cardiac Arrhythmias

เมื่อวันศุกร์ที่ 28 มีนาคม 2568 โรงพยาบาลเมดพาร์ค ร่วมกับ Boston Scientific จัดกิจกรรมสัมมนาวิชาการ Cardiac Arrhythmia Conference ในหัวข้อ Advances in Diagnosis and Management of Cardiac Arrhythmias โดยมีอาจารย์แพทย์ผู้ทรงคุณวุฒิด้านสรีระวิทยาไฟฟ้าหัวใจ ที่มีชื่อเสียงทั้งในประเทศไทยและระดับนานาชาติ ร่วมเป็นวิทยากรบรรยายให้ความรู้แก่บุคลากรทางการแพทย์และประชาชนทั่วไปที่สนใจโดยไม่มีค่าใช้จ่าย ณ ห้องประชุม เดอะ ฟอรัม ชั้น M โดยมี ศ. นพ.สิน อนุราษฎร์ ผู้อำนวยการโรงพยาบาล และประธานเจ้าหน้าที่บริหาร

Boston Scientific ได้รับการรับรอง CE Mark สำหรับกล้องส่องตรวจหลอดลมแบบใช้ครั้งเดียว EXALT(TM) Model B

บริษัทเตรียมวางจำหน่ายในบางตลาดของยุโรป เริ่มมิถุนายนนี้ Boston Scientific Corporation (NYSE: BSX) ประกาศได้รับการรับรอง CE Mark สำหรับกล้องส่องตรวจหลอดลมแบบใช้ครั้งเดียว EXALT(TM) Model B ซึ่ง...

Boston Scientific Completes CE Mark for EXALT(TM) Model B Single-Use Bronchoscope

Company to begin limited market release in Europe in June Boston Scientific Corporation (NYSE: BSX) today announced it has completed CE Mark for the EXALT(TM) Model B Single-Use Bronchoscope, a single-use device...

Symetis and Boston Scientific Reach USD 435 Million Purchase Agreement

- Definitive purchase agreement whereby Boston Scientific will acquire Symetis for $435 million in an all cash, up-front payment Acquisition of Symetis will expand the treatment offerings for patients with aortic valvular heart...

Joining Forces to Tackle Global Stroke Risk

The AF Association announces a collaboration with Boston Scientific Corporation, a global leader in innovative medical technology, to improve awareness of the most common heart rhythm disorder in the world, atrial fibrillation (AF). More than 71 million...

The World Stroke Organization and Boston Scientific Join Forces to Bolster Awareness and Advocacy Efforts

The World Stroke Organization will team with global medical technology leader Boston Scientific Corporation (NYSE:BSX), to further raise awareness and take action in the worldwide fight against...

บอสตัน ไซแอนทิฟิค จัดตั้งองค์กรใหม่ประจำภูมิภาคเอเชียแปซิฟิก

บอสตัน ไซแอนทิฟิค คอร์ปอเรชั่น (Boston Scientific Corporation) (NYSE: BSX) ประกาศจัดตั้งองค์กรใหม่ประจำภูมิภาคเอเชียแปซิฟิก ซึ่งประกอบไปด้วยออสเตรเลีย นิวซีแลนด์ จีน ฮ่องกง อินเดีย ญี่ปุ่น เกาหลีใต้ เอเชียตะวันออกเฉียงใต้ ไต้หวัน และตุรกี...

Boston Scientific Announces New Asia-Pacific Organization

Boston Scientific Corporation (NYSE: BSX) announces the creation of its Asia-Pacific regional organization that includes Australia, New Zealand, China, Hong Kong, India, Japan, South Korea, South East Asia, Taiwan and Turkey. The Company...

Boston Scientific Receives CE Mark Approval for New Apex(TM) PTCA Dilatation Catheters

- New Design Offers Greater Flexibility in the Management of Patients With Complex Atherosclerosis Boston Scientific Corporation (NYSE: BSX) announced today that the Apex(TM) Monorail and Over-The-Wire (OTW) PTCA...