Stroke, Death, and TIA Rates Significantly Reduced With Closed-Cell Carotid Stents

Press Releases »

PARIS--22 May--PRNewswire-AsiaNet/InfoQuest


Data From Multicentre Registry Show Significant Benefit With Closed-Cell Stents in the Treatment of Carotid Artery Stenosis

Boston Scientific Corporation (NYSE: BSX) welcomed results from a large independent registry confirming the benefit of closed-cell stents in patients with carotid artery stenosis. The results, published in the February 2007 issue of the European Journal of Vascular and Endovascular Surgery, show that symptomatic patients treated with closed-cell stents had significantly fewer

complications after the stent was implanted than patients who received open-cell stents. In particular, the Carotid WALLSTENT(TM) was used in 66% of patients in the registry and had the lowest 30-day post-procedural event rate of 1.2% in symptomatic patients.(1)

The 3,179 patients with carotid artery stenosis (narrowing of the arteries in the neck supplying blood to the brain) included in the registry experienced significantly fewer strokes, deaths or transient ischaemic attacks (TIA) within 30 days of the procedure if they received a closed-cell stent (P = 0.002). These stents cover more of the artery wall than open-cell stents because they

have overlapping or fully connecting struts, and have less space between struts (a smaller free cell area). A free cell area of less than 2.5 mm(2) was associated with a post-procedural complication rate of 1.2%, compared with 3.4% for a free cell area of more than 7.5 mm(2) (P = 0.006).(1)

The differences were even greater in patients with symptomatic disease who had already suffered a TIA or stroke and were at higher risk of having another event. In these patients, the post-procedural event rate was 1.3% for closed-cell stents (< 5 mm(2) free cell area), compared with 6.3% for open-cell stents (> 5 mm(2) free cell area) (P < 0.0001).(1) The post-procedural rates

for free cell areas of < 2.5 mm(2) and > 7.5 mm(2) were 1.2% and 7.0%, respectively (P < 0.0001).(1)

Lead investigator Dr. Marc Bosiers, from the Department of Vascular Surgery, St Blasius Academic Hospital, Dendermonde, Belgium, explains the importance of these results: "After carotid angioplasty and stenting, patients are at risk for post-procedural complications within 30 days of the procedure. Closed-cell stents, with their smaller free cell area, provide better scaffolding and lesion coverage and were shown to reduce post-procedural adverse events in our study. In the symptomatic population, late complication rates were highest for the open-cell stents and increased with larger free cell area. For the time being, consideration should be given to the use of stents with a small free cell area, especially in symptomatic patients."

About 4-8% of the population has advanced carotid artery disease,(2) Which puts them at high risk of a TIA or stroke. TIAs involve stroke symptoms lasting only a few minutes or hours and provide an important clinical indicator for potential future stroke, with 10-20% of sufferers having a full-blown stroke within a month.(3) Approximately one-third of people who have had a stroke die

within a month and one-third are left with disabilities.(4)

Carotid artery stenting is a minimally invasive procedure in which a stent is delivered to the site of the blockage and expanded to open the carotid artery and restore blood flow. Stents are tiny wire mesh tubes that are inserted into arteries to help keep the vessel open and therefore maintain blood flow. Closed-cell stents, such as the Carotid Wallstent(TM) and the NexStent(TM) Carotid Stent, have overlapping or fully connecting struts, so they have less free cell area and cover 5-10 times more of the artery wall than

open-cell stents.

The registry recorded outcomes from carotid stenting using a range of closed- and open-cell stent devices at four centres in Belgium and Italy. The closed-cell stents included the Carotid WALLSTENT(TM) (1.08 mm(2) free cell area), Xact(R) (2.74 mm(2)) and NexStent(TM) (4.07 mm(2)). The open-cell stents included Precise(R) (5.89 mm(2)), Exponent(R) (6.51 mm(2)), Protege(R) (10.71 mm(2)) and Acculink(R) (11.48 mm(2)).(x) The Carotid WALLSTENT(TM) was the most frequently used stent and was placed in 2,107 of the 3,179 patients.(1)

"As a leader in the field of cardiovascular device technology, Boston Scientific is delighted that this independent registry confirms the value of closed-cell stents, such as the Carotid WALLSTENT(TM) or the NexStent(TM), which provide excellent scaffolding and lesion coverage," said Jeff Goodman, President of Boston Scientific International. "Our Carotid stents offer a triple combination of benefits for the patient: optimal scaffolding, cell design and radial force."

Boston Scientific Corporation is a worldwide developer, manufacturer and marketer of medical devices whose products are used in a broad range of interventional medical specialties. For more information, please visit www.bostonscientific.com

This press release contains forward-looking statements. Boston Scientific wishes to caution the reader of this press release that actual results may differ from those discussed in the forward-looking statements and may be adversely affected by, among other things, risks associated with new product development and commercialization, clinical trials, intellectual property, regulatory approvals, competitive offerings, Boston Scientific's overall business strategy, and other factors described in Boston Scientific's filings

with the Securities and Exchange Commission.

References

(1) Bosiers M, de Donato G, Deloose K, et al. Does free cell area
influence the outcome in carotid artery stenosis. Eur J Vasc Endovasc Surg
2007;33:135-141.
(2) Dodick DW, Meissner I, Meyer FB, Cloft HJ. Evaluation and management
of asymptomatic carotid artery stenosis. Mayo Clin Proc 2004;79:937-944.
(3) The Stroke Association. Stroke statistics sheet R11
http://www.stroke.org.uk/information/our_publications/factsheets/r11_stroke.html
(last accessed 21 May 2007). (Due to the length of this URL, it may be
necessary to copy and paste this hyperlink into your Internet browser's URL
address field. Remove the space if one exists.)
(4) Global burden of stroke. WHO Atlas of Heart Disease and Stroke 2004.
http://www.who.int/cardiovascular_diseases/en/cvd_atlas_15_burden_stroke.pdf
(last accessed 21 May 2007).
(x)Carotid WALLSTENT and NexStent are trademarks of Boston Scientific
Corporation. Xact and Acculink are trademarks of Abbot Laboratories. Precise
is a trademark of Cordis Corp. Exponent is a trademark of Medtronic Vascular,
Inc. Protege is a trademark of ev3, Inc.

SOURCE: Boston Scientific Corporation

CONTACT: Geraldine Varoqui,

Boston Scientific PR Manager International,

+49-2102-489-461, or

[email protected] , or

Tracy Paul,

BSC press office,

+44-20-7413-3101, or

[email protected]

Web site: http://www.bostonscientific.com

--Distributed by AsiaNet ( www.asianetnews.net )--


ข่าวBoston Scientific+o:healวันนี้

เมดพาร์ค จัดสัมมนาวิชาการ Cardiac Arrhythmia Conference : Advances in Diagnosis and Management of Cardiac Arrhythmias

เมื่อวันศุกร์ที่ 28 มีนาคม 2568 โรงพยาบาลเมดพาร์ค ร่วมกับ Boston Scientific จัดกิจกรรมสัมมนาวิชาการ Cardiac Arrhythmia Conference ในหัวข้อ Advances in Diagnosis and Management of Cardiac Arrhythmias โดยมีอาจารย์แพทย์ผู้ทรงคุณวุฒิด้านสรีระวิทยาไฟฟ้าหัวใจ ที่มีชื่อเสียงทั้งในประเทศไทยและระดับนานาชาติ ร่วมเป็นวิทยากรบรรยายให้ความรู้แก่บุคลากรทางการแพทย์และประชาชนทั่วไปที่สนใจโดยไม่มีค่าใช้จ่าย ณ ห้องประชุม เดอะ ฟอรัม ชั้น M โดยมี ศ. นพ.สิน อนุราษฎร์ ผู้อำนวยการโรงพยาบาล และประธานเจ้าหน้าที่บริหาร

Boston Scientific ได้รับการรับรอง CE Mark สำหรับกล้องส่องตรวจหลอดลมแบบใช้ครั้งเดียว EXALT(TM) Model B

บริษัทเตรียมวางจำหน่ายในบางตลาดของยุโรป เริ่มมิถุนายนนี้ Boston Scientific Corporation (NYSE: BSX) ประกาศได้รับการรับรอง CE Mark สำหรับกล้องส่องตรวจหลอดลมแบบใช้ครั้งเดียว EXALT(TM) Model B ซึ่ง...

Boston Scientific Completes CE Mark for EXALT(TM) Model B Single-Use Bronchoscope

Company to begin limited market release in Europe in June Boston Scientific Corporation (NYSE: BSX) today announced it has completed CE Mark for the EXALT(TM) Model B Single-Use Bronchoscope, a single-use device...

Symetis and Boston Scientific Reach USD 435 Million Purchase Agreement

- Definitive purchase agreement whereby Boston Scientific will acquire Symetis for $435 million in an all cash, up-front payment Acquisition of Symetis will expand the treatment offerings for patients with aortic valvular heart...

Joining Forces to Tackle Global Stroke Risk

The AF Association announces a collaboration with Boston Scientific Corporation, a global leader in innovative medical technology, to improve awareness of the most common heart rhythm disorder in the world, atrial fibrillation (AF). More than 71 million...

The World Stroke Organization and Boston Scientific Join Forces to Bolster Awareness and Advocacy Efforts

The World Stroke Organization will team with global medical technology leader Boston Scientific Corporation (NYSE:BSX), to further raise awareness and take action in the worldwide fight against...

บอสตัน ไซแอนทิฟิค จัดตั้งองค์กรใหม่ประจำภูมิภาคเอเชียแปซิฟิก

บอสตัน ไซแอนทิฟิค คอร์ปอเรชั่น (Boston Scientific Corporation) (NYSE: BSX) ประกาศจัดตั้งองค์กรใหม่ประจำภูมิภาคเอเชียแปซิฟิก ซึ่งประกอบไปด้วยออสเตรเลีย นิวซีแลนด์ จีน ฮ่องกง อินเดีย ญี่ปุ่น เกาหลีใต้ เอเชียตะวันออกเฉียงใต้ ไต้หวัน และตุรกี...

Boston Scientific Announces New Asia-Pacific Organization

Boston Scientific Corporation (NYSE: BSX) announces the creation of its Asia-Pacific regional organization that includes Australia, New Zealand, China, Hong Kong, India, Japan, South Korea, South East Asia, Taiwan and Turkey. The Company...

Boston Scientific Receives CE Mark Approval for New Apex(TM) PTCA Dilatation Catheters

- New Design Offers Greater Flexibility in the Management of Patients With Complex Atherosclerosis Boston Scientific Corporation (NYSE: BSX) announced today that the Apex(TM) Monorail and Over-The-Wire (OTW) PTCA...